1. Information About Carbon Monoxide

Information About Carbon Monoxide Alarms –

What They Can and Cannot Do:
CO alarms provide early warning of the presence of CO, usually before a

View and Download Kidde SMOKE AND CARBON MONOXIDE ALARM user manual online. COMBINATION SMOKE & CARBON MONOXIDE ALARM With 2-LED Display and Peak Level Memory. SMOKE AND CARBON MONOXIDE ALARM Smoke Alarm pdf manual download. Also for: 900-0122-n.

healthy adult would experience symptoms. This early warning is possible,

  • Carbon Monoxide as “CO”. This Kidde carbon monoxide (CO) alarm is an important part of your family’s home safety plan. This alarm has been designed and tested to detect CO buildup in a residential environment. Your alarm is for use specifically in the home. As an owner of a CO alarm, there are some.
  • Information About Carbon Monoxide General Carbon Monoxide Information Carbon monoxide is a colorless, odorless and tasteless poison gas that can be fatal when inhaled. CO inhibits the blood’s capacity to carry oxygen. Periodically review this alarm manual and discuss your CO alarm emer-gency procedure with all the members of your family.
  • View and Download Kidde 900-0259 user manual online. Battery operated CO alarm without Digital display; Battery operated CO alarm with Digital Display and Peak Level memory. 900-0259 Carbon Monoxide Alarm pdf manual download. Also for: 900-0260.
  • THIS CARBON MONOXIDE ALARM IS DESIGNED TO DETECT CARBON MONOXIDE FROM ANY SOURCE OF COMBUSTION. IT IS NOT DESIGNED TO DETECT SMOKE, FIRE, OR ANY OTHER GAS. NOT SUITABLE FOR INSTALLATION IN HAZARDOUS LOCATIONS AS DEFINED IN THE NATIONAL ELECTRIC CODE. KIDDE Safety This manual and the products described in it are copyrighted, with all rights.

however, only if your CO alarm is located, installed and maintained as

described in this guide.
Because carbon monoxide is a cumulative poison, long-term exposures to

low levels may cause symptoms, as well as short-term exposures to high

levels. This Kidde unit has a time-weighted alarm – the higher the level of

CO present, the sooner the alarm will be triggered.
This CO alarm can only warn you of the presence of CO. It does not

prevent CO from occurring, nor can it solve an existing CO problem. If

your unit has alarmed and you’ve provided ventilation by leaving your

windows and doors open, the CO buildup may have dissipated by the

time help responds. Although your problem may appear to be temporar-

ily solved, it’s crucial that the source of the CO is determined and that

the appropriate repairs are made.
This CO alarm is designed to act as a monitor; it is not designed for use

as a short-term testing device to perform a quick check for the presence

of CO.
CO alarms have limitations. Like any other electronic device, CO alarms

are not fool-proof. CO alarms have a limited operational life. You must

test your CO alarm weekly, because it could fail to operate at any time.
If your CO alarm fails to test properly, or if its self-diagnostic test reveals

a malfunction, immediately have the unit replaced. This alarm will not

monitor CO levels while in an error condition.
CO alarms can only sense CO that reaches the unit’s sensor. It’s possible

that CO may be present in other areas without reaching the alarm. The

rate and ability that which CO reaches the alarm may be affected by:

• Doors or other obstructions.
• Fresh air from a vent, an open window or other source.
• CO being present on one level of the home and not reach a CO alarm

installed on a different level. (For example, CO in the basement may

not reach an alarm on the second level, near the bedrooms).

For these reasons, we recommend you provide complete coverage by

placing a CO alarm on every level of the home. Please carefully read all

information in sections 2 and 3 on properly installing this CO alarm.
CO alarms should not be used to detect the presence of natural gas

(methane), propane, butane, or other combustible fuels.

Instruct children never to touch, unplug or otherwise interfere with the

alarm. Warn children of the dangers of CO poisoning.

Advertising
Popular Brands
Popular manuals

AC Powered, Plug-In

Carbon Monoxide Alarm

• Part Number 900-0056 • KN-COP-DP

Digital Display

Displays the level of carbon monoxide the unit is sensing.

Kidde Nighthawk Carbon Monoxide Manual

The unit updates this reading every 15 seconds.

Test/Reset Button

Tests units electronic circuitry and horn and resets the unit during alarm.

Peak Level Button

Displays the peak CO level recorded by the alarm since it was last reset or unplugged.

NEW Alerts user to replace CO alarm

FEATURE: after 7 years of operation

NIGHTHAWKTM

TECHNOLOGY

Most Accurate Carbon Monoxide Alarm*

Description

The Kidde 900-0056 is an AC powered, plug-in carbon monoxide alarm that can be installed easily in any standard wall outlet. The 900-0056 uses advanced technology to monitor for carbon monoxide levels in your home and features a NighthawkTM, electrochemical sensor,

the world’s most accurate carbon monoxide sensing technology*. The digital display feature allows for easy viewing of carbon monoxide levels.

Consumer Benefits

The Kidde 900-0056 AC powered, plug-in carbon monoxide alarm provides you and your family a warning signal against the dangers of carbon monoxide levels in your home. This alarm is easily installed in any of your AC wall outlets. The digital display feature allows for easy viewing of carbon monoxide levels from 30-999PPM (parts per million). The 900-0056 is UL listed and offers a 5-year limited warranty.

Features and Benefits

Digital Display – Displays the level of carbon monoxide the unit is sensing. The unit updates this reading every 15 seconds.

• Peak Level Displays the peak CO level

recorded by the alarm since it was last reset or unplugged.

Test Button – unit’s electronic circuitry and horn and resets the unit during alarm.

AC Powered, Plug-In

Carbon Monoxide Alarm

Architectural and Engineering

Specifications

The carbon monoxide alarm shall be Kidde Unit Number KN-COP- DP (part number 900-0056) or approved equal. It shall be powered by a 120VAC, 60 Hz source. The temperature operating range shall be between 40˚F and 100˚F (4˚C and 38˚C) and the humidity operation range shall be 5% - 95% relative humidity.

The CO sensor shall be of a fuel cell design and shall meet the sensitivity requirements of Underwriters Laboratories UL 2034 Single Station Carbon Monoxide Detectors. The unit shall provide accuracy of +/-20% + 15 parts per million (ppm) when reading CO concentration levels.

The alarm shall include an attached plug that can be installed in any outlet following the UL/NFPA/Manufacturer’s recommended guidelines. The plug shall be capable of being rotated so the alarm remains vertical independent of whether the electrical socket is mounted vertically or horizontally.

The unit shall incorporate a digital display that meets the sensitivity requirements of UL 2034. The display will identify the levels of CO in parts per million (ppm) once that level reaches 30ppm (i.e.:

“abnormal” levels). The display will have a red dot in the lower right corner that will blink to indicate the normal operation.

The alarm shall include a test button that will electronically simulate the presence of CO and cause the unit to go into alarm. This sequence tests the unit’s electronics to ensure proper operation.

The CO sensor will not alarm to levels of CO below 30 ppm and will alarm in the following time range when exposed to the corresponding level of CO.

The alarm shall include a piezoelectric horn that is rated at 85 decibels at 10 feet. When the unit detects carbon monoxide, the alarm pattern will be four (4) short beeps – followed by five (5) seconds of silence – followed by four (4) short beeps. A number reading will appear on the digital display identifying the CO concentration (in ppm). Sap mm inventory management end user manual.

*Based on accuracy claims of major manufacturers

Part Number 900-0056

Unit Number KN-COP-DP

The unit shall include a peak level memory feature that will store the peak CO level sensed since the unit was last reset. The peak CO level stored in the unit’s memory shall be displayed (in ppm) on the digital display by pressing the appropriate button on the unit. The memory shall also be capable of being reset.

The unit shall be listed to UL 2034. It shall also include a 5-year manufacturer’s limited warranty.

Technical Specifications

Part Number:

900-0056

Unit Number:

KN-COP-DP

UPC Number:

7-84608-00560-1

Power Source:

120VAC

Sensor:

Electrochemical

Audio Alarm:

85dB at 10ft

Temperature Range:

40˚F (4.4˚C) to 100˚F (37.8˚C)

Humidity Range:

Up to 95% relative humidity (RH)

Size:

5.65”L x 3.25”W x 1.9”H

Weight:

1lb

Interconnects:

No

Wiring:

Plug-In

LED:

Displays CO concentration in PPM

Warranty:

5 year limited

3.25'

1.9'

Kidde Carbon Monoxide Alarm Manual

5.65'

Ordering Information

Kidde Smoke And Carbon Monoxide Alarm Manual

Clam Shell UPC: 7-84908-00560-1

Part

Dimensions

Case/

Layers/

Skid

Number

I 2 of 5

Pack Quantity

(w x d x h inches)

Weight

Skid

Skid

Weight

900-0056**

N/A

Check out our support resources for your Galaxy S10+ (Unlocked) SM-G975U1 to find manuals, specs, features, and FAQs. You can also register your product to gain access to Samsung's world-class customer support. User manual for samsung galaxy s10 plus.

Individual

7 x 2.5 x 10.75

1lb

N/A

N/A

N/A

900-0056-02

107 84908 00560 8

PDQ (2 units)

7.75 x 6 x 11.75

2lbs

105

3

210lbs

900-0056-07

207 84908 00560 5

Master Pack (4 units)

7.75 x 11.5 x 12

4lbs

80

4

320lbs

900-0056-012

307 84908 00560 2

Cut Case (12 units)

15 x 18 x 12

12lbs

18

3

216lbs

900-0056-036

407 84908 00560 9

Power Tower (36 units)

20 x 24 x 50 (incl. pallet)

36lbs

3

3

108lbs

Resetting Kidde Carbon Monoxide Detector

**Not for sale by individual unit

1

2

4

12

36

UNIT

PDQ

MASTER PACK

CUT CASE

POWER TOWER

Distributed by:

1394 South Third Street, Mebane NC 27302

Kidde Carbon Monoxide User Guide

1-800-880-6788 • www.kiddeus.com

To continue the download you need to go through the captcha:

Instructions For Kidde Carbon Monoxide Alarm